June is the month to catch a weak AC
Cooling in Rupert starts up in July. June is when a system that struggled last summer shows it before the heat actually hits.
Takes about a minute. No obligation.
Cooling in Rupert starts up in July. June is when a system that struggled last summer shows it before the heat actually hits.
AC here only runs July through August. Whatever breaks tends to break early, right when the system first has to work, which makes the cause easier to pin down.

NOAA nClimDiv, 1991–2020 normals
A weak capacitor stops giving the compressor the jolt it needs to start.
A unit that hums or clicks but never cools is almost always a bad capacitor.



Problems tend to show up in the first weeks of the season, when the load hits a part that was already weak.
Find a contractor
A system that runs for hours at a stretch gives you more chances to notice what's off than one that cycles on and off all day. Listen for what changes partway through a long run. Air that starts cool and turns warm. A unit that cycles short, running a few minutes and shutting off before the house actually cools down. A hiss or a rattle that wasn't there when the system kicked on an hour ago. Ice forming on the refrigerant line is another sign, and so is water pooling near the indoor unit. A weak part often holds up for the first few minutes and then falls behind once it has to keep working, so the long runs are when it shows itself.
A system low on refrigerant still runs, but the compressor has to work harder to move what little refrigerant is left. That extra work makes the compressor run hotter, and a compressor that keeps running hot eventually burns out.
Once ice forms on the coil, it blocks the airflow the coil depends on to cool the air, so the system runs longer for less cooling. Shutting the unit off and letting the coil thaw stops the problem from compounding. Leaving it running does not.
Estimates for a typical Minidoka County home, compared with an older unit built to the previous federal minimum, from EIA household energy data, Idaho fuel prices and NOAA climate normals. Your home will differ.
Repair makes sense when a part like a capacitor or contactor has failed.
Replacement makes sense when the compressor has failed or the system uses R-22 refrigerant, which is no longer made.
A diagnostic visit starts with questions. When did it stop cooling. Was it blowing warm air, short cycling, or running nonstop before it quit. Then the tech checks pressures on the refrigerant lines, pulls the capacitor and tests it under load, and checks the amp draw on the compressor to see if it's working harder than it should. They look at the coil for ice or buildup and check the airflow at the vents, since weak airflow and a refrigerant problem can look the same from the thermostat. Electrical connections get checked too. A loose or corroded connection can mimic a failing part. By the end the tech can usually point to the one part causing the trouble, rather than guessing at several.
